Kingspan Range Tribune HE Unvented Hot Water Cylinders⁚ A Comprehensive Guide
This guide provides a detailed overview of Kingspan Range Tribune HE unvented hot water cylinders, covering their features, models, installation, technical specifications, warranty, troubleshooting, and user instructions․
Introduction
Kingspan Range Tribune HE unvented hot water cylinders are a popular choice for homeowners seeking reliable and efficient hot water solutions․ These cylinders are designed to provide a constant supply of hot water on demand, eliminating the need for traditional vented systems․ Made from high-grade duplex stainless steel, they offer exceptional corrosion resistance and durability, ensuring long-lasting performance․ The Tribune HE range features a variety of models, including direct, indirect, and twin-coil indirect options, catering to different heating system configurations and hot water requirements․ This comprehensive guide will delve into the key features and benefits of these cylinders, providing valuable insights for installers and homeowners alike․
Key Features and Benefits
Kingspan Range Tribune HE unvented hot water cylinders boast a range of key features and benefits that contribute to their efficiency, reliability, and user-friendliness․ These cylinders are designed for rapid heating, ensuring a consistent supply of hot water for multiple outlets․ The high-grade duplex stainless steel construction provides exceptional corrosion resistance, safeguarding the cylinder from rust and ensuring long-lasting performance․ The cylinders are also equipped with a strong rust-proofed steel case and are well insulated with environmentally friendly foam, minimizing heat loss and maximizing energy efficiency․ The Tribune HE range offers a variety of sizes, ranging from 90 to 300 liters, allowing homeowners to select the ideal capacity for their hot water needs․ This versatility makes the Tribune HE a suitable choice for various household sizes and hot water usage patterns․
Available Models
The Kingspan Range Tribune HE series encompasses a diverse range of models designed to cater to various hot water needs and preferences․ The Tribune HE Indirect model is an unvented cylinder designed for fast heating via a coil-in-coil heat exchanger, compatible with traditional gas, oil, or electric boilers․ It is crafted from high-grade engineering materials for durability and efficiency․ The Tribune HE Direct model offers a direct electric heating solution, featuring two 3kW immersion heaters․ The primary heat source is a smart immersion heater, while the secondary heater is suitable for off-peak or low tariff electricity use․ Both Direct and Indirect models are available in various sizes, offering flexibility to meet diverse hot water requirements․ Additionally, the Tribune HE series includes models specifically designed for solar water heating systems, further enhancing energy efficiency and sustainability․
Installation and Maintenance Instructions
Proper installation and maintenance are crucial for ensuring optimal performance and longevity of your Kingspan Range Tribune HE unvented hot water cylinder․ These instructions provide detailed guidance on various aspects of the installation process, including storage and handling, component identification, unit siting, general installation procedures, discharge arrangement, and plumbing and electrical connections․ The manual also covers essential maintenance practices, emphasizing the importance of annual servicing by a qualified installer to ensure the system operates efficiently and safely․ Regular maintenance helps prevent potential issues and extends the life of your hot water cylinder, guaranteeing reliable hot water supply for years to come․
Storage and Handling
Prior to installation, the Kingspan Range Tribune HE cylinder should be stored in its original packaging in an upright position to prevent damage and ensure proper ventilation․ It is essential to store the unit in an area free from excessive dampness to avoid corrosion and maintain the integrity of the cylinder’s components․ When handling the cylinder, ensure it is carried upright whenever possible to minimize the risk of damage during transportation․ If lifting or moving the cylinder is necessary, a proper risk assessment should be conducted to ensure the safety of personnel involved․
Component Table
The Kingspan Range Tribune HE component table provides a comprehensive overview of the various models available, including their specific features and configurations․ It outlines the different types of cylinders offered, such as Slimline Direct, Slimline Indirect, Direct, Indirect, Ecocyl Direct, Ecocyl Indirect, Solar Direct, and Solar Indirect models․ The table also details the availability of pre-plumbed models for single and twin zone heating applications․ For each model, the table specifies the presence or absence of features like secondary return, second immersion heater, and dry stat pocket, allowing installers and users to identify the specific components included in their chosen model․
Siting the Unit
The siting of the Kingspan Range Tribune HE unvented cylinder is crucial for optimal performance and efficiency․ The manual emphasizes the importance of minimizing dead leg distances, especially to the point of most frequent use․ This helps ensure efficient hot water delivery and reduces the potential for cold water stagnation․ Outlets located above the cylinder can reduce outlet pressure, with a decrease of 0․1 bar for every 1 meter of height difference․ Therefore, careful consideration should be given to the location of outlets in relation to the cylinder․ Protection from frost is also essential, as freezing temperatures can damage the unit․ Installers should choose a location that is well-insulated and protected from the elements․
General Installation
The installation process for Kingspan Range Tribune HE unvented cylinders requires careful attention to detail and adherence to safety guidelines․ The manual emphasizes the importance of running the cold main pipework through the building to the designated installation site, ensuring it’s not routed near hot water or heating pipework to minimize heat pick-up․ The installer should use isolation valves for both cold and hot water feeds, providing control and safety during installation and maintenance․ It is essential to ensure that the cold feed pipework is properly insulated to prevent heat loss and maintain optimal performance․ The manual also provides guidance on the use of flexible hose connectors, specifying that they should be used for connecting the hot water outlet from the cylinder to the system․ However, the manual cautions against using flexible hoses for the cold feed connection, as they may restrict water flow and impact the overall performance of the system․
Discharge Arrangement
The manual emphasizes the importance of a properly designed discharge arrangement for the Kingspan Range Tribune HE unvented cylinder․ It highlights the potential for prolonged discharge from the temperature pressure (TP) valve, particularly when installed in soil stacks within premises․ Kingspan advises against this practice, as it can lead to prolonged discharge and potentially impact the overall performance of the system․ Installers are responsible for ensuring that the discharge pipework is adequately sized and configured to handle the volume and duration of discharge․ The manual also emphasizes the importance of using appropriate materials for the discharge pipework, ensuring they are compatible with the high temperatures and pressures associated with unvented hot water systems․ Furthermore, the discharge pipework should be properly secured to prevent damage or displacement during operation․ These measures are essential to ensure the safe and reliable operation of the Kingspan Range Tribune HE unvented cylinder․
Plumbing and Electrical Connections
The manual emphasizes the importance of meticulous plumbing and electrical connections for the Kingspan Range Tribune HE unvented cylinder․ It stresses the need for qualified installers to execute these connections, ensuring compliance with all relevant building regulations and safety standards․ The installation process involves connecting the cold water feed, hot water draw-off, and any necessary return pipes to the cylinder․ Installers are instructed to use appropriate fittings and pipework, ensuring proper sealing and pressure ratings․ The manual provides detailed diagrams and instructions for connecting the immersion heaters and any associated controls, including the high limit thermostat and safety devices․ Electrical connections must be made in accordance with local wiring regulations, utilizing appropriately sized cables and protective devices․ The manual emphasizes the importance of testing all plumbing and electrical connections for leaks, continuity, and functionality before commissioning the system․ Properly executed connections ensure the safe and efficient operation of the Kingspan Range Tribune HE unvented cylinder․
Technical Specifications
The Kingspan Range Tribune HE unvented hot water cylinder’s technical specifications provide crucial information for installers and users alike․ These specifications outline the cylinder’s performance capabilities, pressure ratings, and construction details․ The manual highlights the maximum inlet water pressure of 12 bar and the operating pressure of 3․0 bar․ It also details the expansion valve opening pressure of 6․0 bar and the expansion vessel charge pressure of 3․0 bar․ The maximum operating pressure is specified as 7․0 bar, while the opening pressure of the temperature and pressure relief valve (T&P valve) is set at 7․0 bar․ The opening temperature of the T&P valve is also provided․ The manual further outlines the cylinder’s dimensions, volume, and insulation thickness․ It also includes information about the materials used in the cylinder’s construction, including the high-grade Duplex stainless steel inner shell and the fire-retardant polyurethane foam insulation․ These technical specifications are essential for ensuring the correct installation, operation, and maintenance of the Kingspan Range Tribune HE unvented cylinder․
Pressure Specifications
Understanding the pressure specifications of the Kingspan Range Tribune HE unvented hot water cylinder is crucial for ensuring safe and efficient operation․ The manual details these specifications, outlining the maximum inlet water pressure, operating pressure, expansion valve opening pressure, expansion vessel charge pressure, maximum operating pressure, and opening pressure of the temperature and pressure relief valve (T&P valve)․ The maximum inlet water pressure is specified as 12 bar, while the operating pressure is 3․0 bar․ The expansion valve opening pressure is set at 6․0 bar, and the expansion vessel charge pressure is 3․0 bar․ The maximum operating pressure is 7․0 bar, and the opening pressure of the T&P valve is 7․0 bar․ These pressure specifications guide installers and users in ensuring the cylinder operates within safe and optimal pressure ranges, minimizing the risk of malfunctions or damage․ It is essential to adhere to these specifications during installation and maintenance to ensure the long-term performance and safety of the Kingspan Range Tribune HE unvented hot water cylinder․
Cylinder Details and Performance
The Kingspan Range Tribune HE unvented hot water cylinder is engineered with a focus on performance and efficiency․ The user manual provides detailed specifications regarding the cylinder’s capacity, heating time, and energy efficiency; For instance, the Tribune Direct Slimline models, ranging from 60 to 210 liters, offer various heating times and energy efficiency ratings․ The manual presents tables detailing these performance parameters for each model, allowing users to choose the cylinder that best suits their hot water needs and energy consumption goals․ The manual also highlights the cylinder’s construction materials, emphasizing the use of high-grade duplex stainless steel for enhanced corrosion resistance and durability․ The insulation details, including the use of fire-retardant polyurethane foam, are outlined to ensure users understand the cylinder’s thermal efficiency and safety features․ By providing comprehensive information on cylinder details and performance, Kingspan empowers users to make informed decisions and maximize the benefits of their chosen model․
Warranty and Support
Kingspan Renewables provides comprehensive warranty coverage for the Tribune HE unvented hot water cylinder․ The user manual outlines the warranty terms and conditions, including the duration of coverage for different components․ A standard two-year warranty is offered on all parts against faulty manufacture or materials from the date of installation․ The manual emphasizes the importance of registering the product online within 30 days of purchase to ensure the full warranty period applies․ Failure to register may result in a reduced warranty period․ Kingspan also provides a dedicated technical helpline and fax line for customers seeking support or assistance with their Tribune HE cylinder․ The contact details for these services are included in the user manual, allowing users to easily access technical guidance and troubleshooting support․ By providing detailed warranty information and readily available support channels, Kingspan demonstrates its commitment to customer satisfaction and ensures peace of mind for users of their Tribune HE unvented hot water cylinders․
Troubleshooting and Fault Finding
The Kingspan Range Tribune HE user manual provides valuable guidance for troubleshooting common issues that may arise with the cylinder․ The manual outlines a systematic approach to fault finding, starting with identifying the symptoms and narrowing down the potential causes․ It covers various scenarios, such as lack of hot water, noisy operation, and temperature fluctuations․ For each issue, the manual provides clear instructions on how to check specific components, such as the immersion heater, pressure relief valve, and expansion vessel․ It also suggests potential solutions, including resetting the thermostat, adjusting the pressure, or checking for leaks․ The manual emphasizes the importance of contacting a qualified installer for any repairs or maintenance that are beyond the scope of the user’s capabilities․ By providing comprehensive troubleshooting information, the manual empowers users to identify and address common issues, ensuring the smooth and reliable operation of their Tribune HE cylinder․
Spare Parts
The Kingspan Range Tribune HE user manual emphasizes the importance of using genuine Kingspan spare parts for any repairs or replacements․ The manual provides details on how to obtain these parts, highlighting the importance of contacting Range Cylinders directly․ The manual also includes a list of common spare parts, such as immersion heaters, pressure relief valves, expansion vessels, and thermostats․ It provides information on the part numbers and specifications to ensure that users order the correct parts․ The manual advises against using non-genuine parts, as these may compromise the performance and safety of the cylinder․ By using genuine Kingspan spare parts, users can ensure that their Tribune HE cylinder continues to operate efficiently and safely for years to come․